Slab On Grade Floors Have At Least A 4 Air Space Between The Floor And Ground

The design of the slab on grade is engineered by the structural engineer.
Slab on grade floors have at least a 4 air space between the floor and ground. An expansion space of 3 4 inch should be left at vertical obstructions. On the next job buford had to gluedown finger block parquet in a new house. If i remove the first floor external slab on grade floors as i have stated it is interesting that before and after the removal of the floors. In many areas building code has fallen behind common sense on what specification of insulation to use under a slab it is common to install as little as r5 insulation below slab floors making that about the weakest point in a building envelope as walls are.
Hvac air ducts located inside concrete slab floors invite a surprisingly broad range of building problems that fall into two broad categories. A slab on grade does not have any voids below it and can be as thin as 4 inches. 4 4 checklist for design construction of slab on grade foundations. Slab on grade floors with a floor surface less than 12 inches below grade should be insulated in accordance with information provided in the insulation and fenestration requirements by component table which is reproduced following this paragraph.
This article describes heating and air conditioning ducts that have been placed in or beneath concrete floor slabs. Depending on where the measurement was made the slab may pass or fail the specified. The checklist could be used many ways. The slab on grade can be installed on the virgin ground a layer of stone or porous material etc.
In climate zones 4 and 5 the code requires certain slabs below grade slabs that are less than 12 in. 2015 iecc irc section r402 2 10 n1102 2 10 slab on grade floors. Common tolerances were 1 8 inch or 1 4 inch in 10 feet. Aci 302 1r provides guidelines and recommendations on materials and slab construction.
If there are concerns regarding the ability of the earth to support the slab on grade the. This checklist serves as a chapter summary helps review the completeness of construction drawings and specifications and provides general guidance on project management. Functional troubles such as lack of air flow or collapsed ductwork and environmental problems such as. Hvac ductwork in floor slabs.
Concrete floor slab flatness and levelness traditionally allowable tolerances of concrete floor slabs were determined by checking the slab surface with a 10 foot straightedge. The fallacy of the straightedge method was the location of the measurement. 1 2 of the first floor is over a conditioned space and one half is slab on grade. Below grade to have r 10 vertical insulation at the slab perimeter extending downward from the top of the slab to a depth of at least 2 ft.
For comfort and to save money that s why. From insulating a slab on grade. He checked the slab for moisture filled in a few low spots and glued down the floor using the recommended trowel and adhesive. Why insulate under a slab on grade foundation.
1 2 4 aci committee 325 addresses the structural. So i defined this floor as over an unconditioned space in the dd wizard as this should result in a reasonable average. Insulating below slab on grade foundations.